Part numbers:
Fixing Film - FM1-Z407, FM1-Z407-000, FM3-5949, FM3-5949-000, FM3-5950, FM3-5950-000, FM3-5950-010, FM3-5950-020
Pressure Roller - FC0-5061, FC0-5061-000, FC8-4906, FC8-4906-000
Fuser Unit - FM3-5947, FM3-5947-010, FM4-8420, FM4-8420-000, FM4-8420-010, FM3-5947-000
Common error codes:
E001 0000 05 =Abnormal high temperature in Main Thermistor 1, 2
E001 0001 05 = Abnormal high temperature in Sub Thermistor 1, 2
E001 0003 05 = High temperature error detected by hardware
E003 0000 05 = Error detected when the Heater is ON
E003 0001 05 = Abnormal detection during paper feeding
E003 0002 05 = Abnormal low temperature when the Heater is ON
(disconnection detected)
E003 0004 05 = Timeout at start-up
E004 0000 05 = Thermistor disconnection detection error
E004 0001 05 = Error in detection of welding with fixing relay
E009 0000 05 = Error in engagement
E009 0001 05 = Error in disengagement
E009 0002 05 = Pressure error (it is highly possible that grease is scattered
on the surface of the cam.)
Compatible models: